Control Panel Servicing, Repairs & Installations

Servicing, fault-finding, repairs and new control panels for pump stations and treatment plants, across Surrey, Sussex, Kent, Hampshire and London.

Servicing and
repair engineers
24/7
call-outs
Clear report
after every visit
Our own vans
and tankers
34 years
in drainage

The basics

What does a control panel do?

The control panel is the brain of your pump station. It reads the floats, switches the pumps on and off, swaps them over between runs and sets off the alarm if something goes wrong.

Control panel faults often show up as a pump problem, so see pump station repairs, or keep both in good order with regular pump station servicing.

We do this work across Surrey, West Sussex, East Sussex, Kent, Hampshire and London, with tankers and engineers in each area most days.

When a panel fails, a perfectly good pump can sit there doing nothing while the level rises. That’s why the panel is checked on every service, and why a fault needs fixing quickly.

Inside the panel

Getting to know your control panel

Every panel is different, but most twin pump panels have these parts. Hover over or tap the numbers to see what each one does.

A twin pump control panel The front of a typical twin pump control panel, showing the mains isolator, power lamp, run and fault lamps for each pump, hand-off-auto switches, hours-run meters, the high-level alarm lamp with mute and reset buttons, an external alarm beacon and the cable entries underneath. PUMP CONTROL POWER P1 RUNP1 FAULT P2 RUNP2 FAULT HIGH LEVEL HOAPUMP 1HOAPUMP 2 01482.6P1 HOURS02482.6P2 HOURS MUTE RESET ISOLATOR 12345678
  1. 1Mains isolatorSwitches off all power to the panel so the pumps can be worked on safely.
  2. 2Power lampShows the panel has power. If it’s out, nothing will pump.
  3. 3Run and fault lampsShow which pump is running, and light up if a pump trips or fails.
  4. 4Hand, off, auto switchesAuto for normal use. Hand runs a pump manually for testing, so leave that to an engineer.
  5. 5Hours-run metersRecord how long each pump has run. Uneven hours can point to a problem.
  6. 6High-level alarm, mute and resetWarns you the level is too high. Mute silences the buzzer, but the fault still needs fixing.
  7. 7Alarm beaconA flashing light you can see from outside, so an alarm isn’t missed.
  8. 8Cable entriesWhere the pump, float and power cables come in. Water getting in here causes faults.

What we do

Servicing, repairs and new panels

Servicing

Testing lamps, switches, meters, alarms and wiring, and checking for water, heat damage or loose connections.

Fault-finding and repairs

Replacing failed relays, contactors, breakers, boards and float inputs, day or night.

New and replacement panels

Panels to suit your pumps and power supply, installed, commissioned and handed over with documentation.

Alarm and telemetry upgrades

Adding beacons, louder buzzers or remote alerts to an older panel.

Warning signs

What happens when a control panel fails?

A failed panel can stop the pumps starting, stop them switching off, or stop the alarm working, which is the worst of all, because nothing tells you the level is rising.

In a foul pump station, that means waste backing up into the property or garden. In a surface water station, it can mean flooding in heavy rain.

Signs of a panel problem

  • Alarms sounding when they shouldn’t, or not when they should
  • Pumps running constantly, or not at all
  • Fault lamps lit or breakers tripping
  • Unexpected power loss or resets
  • Water, condensation or a burning smell inside
Book a service

On the day

What happens on a control panel visit

  1. We isolate and inspect

    Power off, then a close look for damage, water and loose connections.

  2. We test

    Every input, output, lamp and alarm is tested with the pumps and floats.

  3. We repair or replace

    Faulty parts replaced, or a new panel recommended if yours is beyond economical repair.

  4. We commission and explain

    We test the whole system and show you what the lamps and switches mean.

Why Clearmasters

Why choose Clearmasters?

We look after the whole pump station, not just the panel, so we can tell whether a fault is electrical, mechanical or something in the chamber.

Ask us a question

Always on hand

Planned servicing at a time that suits you, and 24/7 call-outs when something goes wrong.

Straight answers

We explain what we found in plain English, and give you honest advice on what needs doing now and what can wait.

Trained engineers

Our engineers hold current confined space entry certificates and work on treatment plants, pump stations and drainage every day.

24/7 fault call-outs

Panel faults don’t wait for office hours, and neither do we.

What our customers say

Questions answered

Control panel FAQs

What does ‘hand, off, auto’ mean?

Auto is normal running, where the floats control the pumps. Hand runs a pump manually for testing, and Off stops it. Leave it on Auto unless an engineer tells you otherwise, as running a pump dry in Hand can damage it.

Can I just reset the alarm?

You can mute the buzzer, but the fault that caused the alarm is still there. Call us so we can find out why it went off.

My panel keeps tripping. What causes that?

Often a pump fault, water getting into the panel or a failing component. It needs an engineer to find the cause, as repeatedly resetting it can do more damage.

Can you replace an old panel?

Yes. We supply and install panels to suit your pumps and power supply, and commission them fully.

Can you add remote alerts?

Yes. We can add alarm and telemetry options so you’re told about a problem even when you’re not there.

Got a different question? Call 03333 233566 or send us a message.

Related services

Fully accredited & compliant

We're independently vetted and certified so you can trust who you're letting onto your site.

SafeContractor

Health & safety pre-qualification accreditation, verifying our processes meet recognised safety standards.

RISQS

Railway Industry Supplier Qualification Scheme — approved to work safely within the rail industry supply chain.

Achilles UVDB

Utilities Vetting Database membership, confirming we meet the utilities sector's supply chain standards.

Trading Standards Approved

Vetted and approved under the local authority's trusted trader scheme for honesty and fair dealing.

NADC Member

Members of the National Association of Drainage Contractors, the UK trade body for the drainage industry.

Registered Waste Carrier

Registered with the Environment Agency, so your waste is handled and disposed of fully within the law.

Call Email