The short answer
What does a treatment plant alarm mean?
A treatment plant alarm usually means one of four things: the air supply has failed (or on a Klargester BioDisc, the discs have stopped turning), the water level is too high, the plant has lost power, or a service is due. The first three need attention the same day, because the bacteria that clean the water start to suffer quickly.
Alarm sounding right now?
Mute the buzzer, but don’t switch the plant off. Cut your water use, don’t lift the lids, and note any message on the panel. Then call our 24/7 line.
Interactive
Treatment plant alarm checker
Choose your plant, then what you’re seeing, to find out what it usually means and what you can safely check.
1. Your plant
2. What you’re seeing
Not sure of your plant? The make is usually on the lid or the control unit, or send us a photo and we’ll tell you.
Read the screen
Common treatment plant alarm messages
Panels with a screen tell you what’s wrong. The exact wording depends on the make and the age of the panel, but these are the ones we see most.
| Message | What it usually means | What you can do | How soon |
|---|---|---|---|
| F1 to F8 (older Klargester panels) | A fault code instead of words. F1 is no power, F8 is loss of rotation, and the others are blower pressure, high level or blown fuses. | See our Klargester F code table below. | Depends on code |
| Mains failure, power failure | The plant has lost its power supply. Panels with a battery can still alarm. | Check the breaker or RCD and reset it once. If it trips again, leave it off. | Today |
| Loss of rotation | Klargester BioDisc: the disc pack has stopped turning. | Check the power once. Don’t switch the plant off or lift the covers. | Today |
| Blower pressure, low air pressure, Fault Compressor | The blower or compressor isn’t delivering enough air. | Listen for the blower, check its breaker and keep the vents clear. | Today |
| High level | Water is higher than it should be, often a blocked outlet, failed pump or waterlogged drainage field. | Cut your water use right down. Don’t lift the lids. | Today |
| Fuse messages, such as “Motor/blower fuse” | A fuse in the control panel has blown, usually because something downstream has a fault. | Leave it to an engineer: a blown fuse is a symptom, not the cause. | Today |
| Low battery | The panel’s backup battery is running low. | Not urgent, but have it replaced so the alarm still works in a power cut. | Soon |
| Service due | The service interval set in the panel has been reached. | Book a service. The plant is still working. | Soon |
| Set the clock | Graf one2clean: the date and time need setting, often after a power cut. | Set them in the menu. Not a fault. | You can fix it |
Older Klargester panels
Klargester fault codes F1 to F8
Many BioDisc plants still have Klargester’s older control panel, which flashes a beacon and shows a short code instead of a message. These are the codes and what they mean, from Kingspan’s BioDisc manuals.
| Code | What it means | What to do | How soon |
|---|---|---|---|
| F1 | No power to the unit | There’s no fuse for this on the panel itself. Check the breaker or fuse for the plant in your consumer unit and reset it once. | Today |
| F2 | Blower pressure has failed | On plants fitted with a blower pressure kit. The air supply has dropped: listen for the blower, then call us. | Today |
| F3 | High level alarm | Where fitted, usually on plants with a pumped outlet. The water is too high. Cut your water use right down. | Today |
| F4 | Fuse to the motor has failed | The fuse feeding the motor (or blower and motor) has blown, so on a BioDisc the discs will stop. A fuse blows for a reason, so it needs an engineer. | Today |
| F5 | Fuse to the discharge pump has failed | On plants with a pumped outlet. The pump has stopped, so the level will rise. Cut your water use. | Today |
| F6 | Fuse to the chemical dosing pump has failed | Only on plants with chemical dosing. Treatment carries on, but the dosing has stopped. | Soon |
| F7 | Fuse to the recirculation pump has failed | Only on plants with sludge recirculation. Book a repair. | Soon |
| F8 | Loss of rotation alarm | The disc pack has stopped turning. Don’t switch the plant off or lift the covers. | Today |
| -- | A fault has corrected itself | Something tripped and then cleared. The orange reset button next to the display clears it. If it keeps coming back, call us. | Keep an eye on it |
Don’t change the fuses yourself. Kingspan says the power must be isolated before any cover is lifted, and a blown fuse (F4 to F7) usually means the motor or a pump has a fault. Note the code and call us: our engineers carry the common parts.
Brand by brand
How each make of plant raises an alarm
Based on each manufacturer’s own manuals and guidance. Panels change over the years, so yours may differ slightly.
Klargester BioDisc
A pack of discs turned slowly by a motor and gearbox. Newer panels alarm on “Loss of rotation” if the discs stop, and on mains failure, high level, low battery and service due. Older panels show a code from F1 to F8 instead: see the F code table. Kingspan says to leave the motor switched on.
Klargester BioFicient and BioTec
Air-blown plants using the same family of Klargester control panels. “Blower pressure” is the message to look out for: the air supply has dropped.
Graf one2clean
Treats in batches, twice a day, with the compressor in the control cabinet. Green light means normal, red means a fault, and the display names it. It restarts itself after a power cut.
WPL Diamond
Air-blown, with a blower in a kiosk. A flashing beacon on the kiosk means the blower isn’t delivering air. Pumped-outlet models also have a high-level alarm.
Tricel Novo
Air-blown. The alarm sounds for a fault with the air blower or the discharge pump. The buzzer can be muted, and resets itself once the fault is fixed.
Rewatec (Conder) ASP
A round tank with a central aerated zone, kept alive by a blower. Alarm arrangements vary with age and model, but a silent blower is the first thing to check.
Marsh Ensign
Three-stage plants with no moving parts in the tank. Ensign Ultra plants have a compressor with a low-pressure alarm.
How they work
Why treatment plants have alarms
Unlike a septic tank, a treatment plant relies on moving parts and a power supply to keep its bacteria alive. The alarm watches the parts that matter most.
Air-blown plants
Most modern plants, including the WPL Diamond, Tricel Novo, Rewatec ASP, Marsh Ensign and Klargester BioFicient. A blower or compressor pumps air into the tank. The alarm usually watches the air pressure, and often the water level.
Rotating disc plants
The Klargester BioDisc. A motor and gearbox turn a pack of discs that carry the bacteria in and out of the water. The alarm watches that the discs are turning, plus the power and water level.
Batch plants
The Graf one2clean treats sewage in cycles, controlled by a unit in the control cabinet that runs the compressor. The display tells you which part has a fault.
Not sure which you have, or how they differ from a septic tank? See septic tank vs cesspit vs treatment plant.
Step by step
What to do when your treatment plant alarm sounds
Mute, don’t switch off
Use the mute or accept button on the panel. Leave the plant itself switched on, so the bacteria keep getting air.
Note what it says
Write down any message or take a photo of the panel. Use the checker and message table above.
Listen
Stand by the blower housing or kiosk. A steady hum is normal. Silence, rattling or a burning smell is not.
Check the power
Look for a tripped breaker or RCD for the plant in your consumer unit. Reset it once. If it trips again, leave it off.
Cut your water use
Especially if the alarm is a high level. Avoid baths, showers, the washing machine and the dishwasher until it’s checked.
Call us
Ring 03333 233577, 24 hours a day. Tell us the make, the message and what you’ve checked.
Stay safe
What not to do
Don’t switch the plant off
It stops the noise but starts killing the bacteria. Mute the buzzer instead.
Don’t lift the lids or climb in
Treatment plants can hold dangerous gases, and the tanks are deep. Leave inspections to trained engineers.
Don’t keep resetting the breaker
If it trips again straight away, something has a fault. Resetting it over and over can make it worse.
Don’t pour in additives or bleach
They won’t fix a mechanical fault, and strong chemicals can harm the bacteria that treat the sewage.
Prevention
How to stop treatment plant alarms
Most alarms come from parts that wear gradually: blower diaphragms and filters, motors and belts, pumps and floats. A regular service catches them before they stop the plant. Our guide to how often to service a treatment plant explains what happens on the visit.
A treatment plant service usually includes: checking the blower or motor and replacing worn parts, cleaning filters, testing the alarm and any pumps, checking the water at the outlet, measuring the sludge and advising when it needs emptying, with a written record of anything that needs attention.
Between services, listen for the blower now and then, keep the kiosk vents clear, and keep wipes, fat and strong chemicals out of the drains. Our guide to what not to flush explains why.
| Manufacturer guidance | Service at least |
|---|---|
| Klargester BioDisc | Once a year, with desludging every 6 to 12 months depending on model |
| WPL Diamond | Inspection every 6 months |
| Graf one2clean | At least once a year by a specialist |
| Tricel Novo | Once a year |
From each manufacturer’s manual. Busy households, holiday lets and commercial sites may need more. Check your plant’s own manual, or ask us.
Treatment plant servicing DesludgingQuestions answered
Treatment plant alarm FAQs
What do the F codes on my Klargester control panel mean?
Older Klargester panels show a code instead of a message. F1 means no power to the unit, F2 blower pressure has failed, F3 the high level alarm, F4 the motor fuse has failed, F5 the discharge pump fuse, F6 the chemical dosing pump fuse, F7 the recirculation pump fuse, and F8 loss of rotation. Two dashes (--) mean a fault has corrected itself.
What does F1 mean on a Klargester BioDisc?
F1 means there’s no power to the unit. Check the breaker or fuse for the plant in your consumer unit and reset it once. If it trips again, leave it off and call us, as the motor or cable may have a fault.
Can I switch my treatment plant off to stop the alarm?
No. Mute the buzzer instead. Switching the plant off stops the air or the discs that keep the bacteria alive, so treatment gets worse the longer it’s off. On a Klargester BioDisc, Kingspan says the motor should be left switched on.
Why did my treatment plant alarm go off after a power cut?
Many panels raise an alarm when the power returns, to tell you the supply was lost. Most plants restart on their own, but check the blower is humming, or on a BioDisc that the discs are turning. If the alarm doesn’t clear, call us.
Can I still use the toilet when the alarm is on?
Keep water use to a minimum until it’s been checked, especially if the alarm is a high level or the plant is backing up. Avoid baths, showers, the washing machine and the dishwasher, and flush only when you need to.
How long can a treatment plant go without power?
Not long without treatment suffering. Graf, for example, says cleaning is reduced or not possible if its one2clean is off for more than 24 hours. After a long outage, get it checked.
The alarm says “Service due”. Is something wrong?
No. It means the service interval set in the control panel has been reached. The plant is still working, but book a service so it stays that way.
Do you service and repair my make of plant?
We service and repair Klargester, Graf, WPL Diamond, Tricel, Rewatec (Conder) and Marsh plants, among others, across Surrey, Sussex, Kent, Hampshire and London. Our engineers carry most common parts.
The alarm keeps coming back after I reset it. What should I do?
Stop resetting it and call us. An alarm that returns means the fault is still there, and repeatedly resetting a tripped breaker can make an electrical fault worse.
Got a different question? Call 03333 233566 or send us a message.