Treatment Plant Alarm Going Off? What It Means, Brand by Brand

What your sewage treatment plant alarm is telling you, including the F1 to F8 codes on older Klargester panels, the messages you might see on Klargester, Graf, WPL, Tricel, Rewatec (Conder) and Marsh plants, what you can safely check, and when to call.

By Daniel Jee, Director · Updated November 2026 · 8 minute read

The short answer

What does a treatment plant alarm mean?

A treatment plant alarm usually means one of four things: the air supply has failed (or on a Klargester BioDisc, the discs have stopped turning), the water level is too high, the plant has lost power, or a service is due. The first three need attention the same day, because the bacteria that clean the water start to suffer quickly.

Alarm sounding right now?

Mute the buzzer, but don’t switch the plant off. Cut your water use, don’t lift the lids, and note any message on the panel. Then call our 24/7 line.

Call 03333 233577

Interactive

Treatment plant alarm checker

Choose your plant, then what you’re seeing, to find out what it usually means and what you can safely check.

1. Your plant

2. What you’re seeing

Not sure of your plant? The make is usually on the lid or the control unit, or send us a photo and we’ll tell you.

Read the screen

Common treatment plant alarm messages

Panels with a screen tell you what’s wrong. The exact wording depends on the make and the age of the panel, but these are the ones we see most.

MessageWhat it usually meansWhat you can doHow soon
F1 to F8 (older Klargester panels)A fault code instead of words. F1 is no power, F8 is loss of rotation, and the others are blower pressure, high level or blown fuses.See our Klargester F code table below.Depends on code
Mains failure, power failureThe plant has lost its power supply. Panels with a battery can still alarm.Check the breaker or RCD and reset it once. If it trips again, leave it off.Today
Loss of rotationKlargester BioDisc: the disc pack has stopped turning.Check the power once. Don’t switch the plant off or lift the covers.Today
Blower pressure, low air pressure, Fault CompressorThe blower or compressor isn’t delivering enough air.Listen for the blower, check its breaker and keep the vents clear.Today
High levelWater is higher than it should be, often a blocked outlet, failed pump or waterlogged drainage field.Cut your water use right down. Don’t lift the lids.Today
Fuse messages, such as “Motor/blower fuse”A fuse in the control panel has blown, usually because something downstream has a fault.Leave it to an engineer: a blown fuse is a symptom, not the cause.Today
Low batteryThe panel’s backup battery is running low.Not urgent, but have it replaced so the alarm still works in a power cut.Soon
Service dueThe service interval set in the panel has been reached.Book a service. The plant is still working.Soon
Set the clockGraf one2clean: the date and time need setting, often after a power cut.Set them in the menu. Not a fault.You can fix it

Older Klargester panels

Klargester fault codes F1 to F8

Many BioDisc plants still have Klargester’s older control panel, which flashes a beacon and shows a short code instead of a message. These are the codes and what they mean, from Kingspan’s BioDisc manuals.

CodeWhat it meansWhat to doHow soon
F1No power to the unitThere’s no fuse for this on the panel itself. Check the breaker or fuse for the plant in your consumer unit and reset it once.Today
F2Blower pressure has failedOn plants fitted with a blower pressure kit. The air supply has dropped: listen for the blower, then call us.Today
F3High level alarmWhere fitted, usually on plants with a pumped outlet. The water is too high. Cut your water use right down.Today
F4Fuse to the motor has failedThe fuse feeding the motor (or blower and motor) has blown, so on a BioDisc the discs will stop. A fuse blows for a reason, so it needs an engineer.Today
F5Fuse to the discharge pump has failedOn plants with a pumped outlet. The pump has stopped, so the level will rise. Cut your water use.Today
F6Fuse to the chemical dosing pump has failedOnly on plants with chemical dosing. Treatment carries on, but the dosing has stopped.Soon
F7Fuse to the recirculation pump has failedOnly on plants with sludge recirculation. Book a repair.Soon
F8Loss of rotation alarmThe disc pack has stopped turning. Don’t switch the plant off or lift the covers.Today
--A fault has corrected itselfSomething tripped and then cleared. The orange reset button next to the display clears it. If it keeps coming back, call us.Keep an eye on it

Don’t change the fuses yourself. Kingspan says the power must be isolated before any cover is lifted, and a blown fuse (F4 to F7) usually means the motor or a pump has a fault. Note the code and call us: our engineers carry the common parts.

Brand by brand

How each make of plant raises an alarm

Based on each manufacturer’s own manuals and guidance. Panels change over the years, so yours may differ slightly.

Klargester BioDisc

A pack of discs turned slowly by a motor and gearbox. Newer panels alarm on “Loss of rotation” if the discs stop, and on mains failure, high level, low battery and service due. Older panels show a code from F1 to F8 instead: see the F code table. Kingspan says to leave the motor switched on.

Klargester BioDisc servicing and repairs →

Klargester BioFicient and BioTec

Air-blown plants using the same family of Klargester control panels. “Blower pressure” is the message to look out for: the air supply has dropped.

Klargester BioFicient servicing and repairs →

Graf one2clean

Treats in batches, twice a day, with the compressor in the control cabinet. Green light means normal, red means a fault, and the display names it. It restarts itself after a power cut.

Graf one2clean servicing and repairs →

WPL Diamond

Air-blown, with a blower in a kiosk. A flashing beacon on the kiosk means the blower isn’t delivering air. Pumped-outlet models also have a high-level alarm.

WPL Diamond servicing and repairs →

Tricel Novo

Air-blown. The alarm sounds for a fault with the air blower or the discharge pump. The buzzer can be muted, and resets itself once the fault is fixed.

Tricel Novo servicing and repairs →

Rewatec (Conder) ASP

A round tank with a central aerated zone, kept alive by a blower. Alarm arrangements vary with age and model, but a silent blower is the first thing to check.

Rewatec (Conder) ASP servicing and repairs →

Marsh Ensign

Three-stage plants with no moving parts in the tank. Ensign Ultra plants have a compressor with a low-pressure alarm.

Marsh Ensign servicing and repairs →

How they work

Why treatment plants have alarms

Unlike a septic tank, a treatment plant relies on moving parts and a power supply to keep its bacteria alive. The alarm watches the parts that matter most.

Air-blown plants

Most modern plants, including the WPL Diamond, Tricel Novo, Rewatec ASP, Marsh Ensign and Klargester BioFicient. A blower or compressor pumps air into the tank. The alarm usually watches the air pressure, and often the water level.

Rotating disc plants

The Klargester BioDisc. A motor and gearbox turn a pack of discs that carry the bacteria in and out of the water. The alarm watches that the discs are turning, plus the power and water level.

Batch plants

The Graf one2clean treats sewage in cycles, controlled by a unit in the control cabinet that runs the compressor. The display tells you which part has a fault.

Not sure which you have, or how they differ from a septic tank? See septic tank vs cesspit vs treatment plant.

Step by step

What to do when your treatment plant alarm sounds

  1. Mute, don’t switch off

    Use the mute or accept button on the panel. Leave the plant itself switched on, so the bacteria keep getting air.

  2. Note what it says

    Write down any message or take a photo of the panel. Use the checker and message table above.

  3. Listen

    Stand by the blower housing or kiosk. A steady hum is normal. Silence, rattling or a burning smell is not.

  4. Check the power

    Look for a tripped breaker or RCD for the plant in your consumer unit. Reset it once. If it trips again, leave it off.

  5. Cut your water use

    Especially if the alarm is a high level. Avoid baths, showers, the washing machine and the dishwasher until it’s checked.

  6. Call us

    Ring 03333 233577, 24 hours a day. Tell us the make, the message and what you’ve checked.

Stay safe

What not to do

Don’t switch the plant off

It stops the noise but starts killing the bacteria. Mute the buzzer instead.

Don’t lift the lids or climb in

Treatment plants can hold dangerous gases, and the tanks are deep. Leave inspections to trained engineers.

Don’t keep resetting the breaker

If it trips again straight away, something has a fault. Resetting it over and over can make it worse.

Don’t pour in additives or bleach

They won’t fix a mechanical fault, and strong chemicals can harm the bacteria that treat the sewage.

Prevention

How to stop treatment plant alarms

Most alarms come from parts that wear gradually: blower diaphragms and filters, motors and belts, pumps and floats. A regular service catches them before they stop the plant. Our guide to how often to service a treatment plant explains what happens on the visit.

A treatment plant service usually includes: checking the blower or motor and replacing worn parts, cleaning filters, testing the alarm and any pumps, checking the water at the outlet, measuring the sludge and advising when it needs emptying, with a written record of anything that needs attention.

Between services, listen for the blower now and then, keep the kiosk vents clear, and keep wipes, fat and strong chemicals out of the drains. Our guide to what not to flush explains why.

Manufacturer guidanceService at least
Klargester BioDiscOnce a year, with desludging every 6 to 12 months depending on model
WPL DiamondInspection every 6 months
Graf one2cleanAt least once a year by a specialist
Tricel NovoOnce a year

From each manufacturer’s manual. Busy households, holiday lets and commercial sites may need more. Check your plant’s own manual, or ask us.

Treatment plant servicing Desludging

Questions answered

Treatment plant alarm FAQs

What do the F codes on my Klargester control panel mean?

Older Klargester panels show a code instead of a message. F1 means no power to the unit, F2 blower pressure has failed, F3 the high level alarm, F4 the motor fuse has failed, F5 the discharge pump fuse, F6 the chemical dosing pump fuse, F7 the recirculation pump fuse, and F8 loss of rotation. Two dashes (--) mean a fault has corrected itself.

What does F1 mean on a Klargester BioDisc?

F1 means there’s no power to the unit. Check the breaker or fuse for the plant in your consumer unit and reset it once. If it trips again, leave it off and call us, as the motor or cable may have a fault.

Can I switch my treatment plant off to stop the alarm?

No. Mute the buzzer instead. Switching the plant off stops the air or the discs that keep the bacteria alive, so treatment gets worse the longer it’s off. On a Klargester BioDisc, Kingspan says the motor should be left switched on.

Why did my treatment plant alarm go off after a power cut?

Many panels raise an alarm when the power returns, to tell you the supply was lost. Most plants restart on their own, but check the blower is humming, or on a BioDisc that the discs are turning. If the alarm doesn’t clear, call us.

Can I still use the toilet when the alarm is on?

Keep water use to a minimum until it’s been checked, especially if the alarm is a high level or the plant is backing up. Avoid baths, showers, the washing machine and the dishwasher, and flush only when you need to.

How long can a treatment plant go without power?

Not long without treatment suffering. Graf, for example, says cleaning is reduced or not possible if its one2clean is off for more than 24 hours. After a long outage, get it checked.

The alarm says “Service due”. Is something wrong?

No. It means the service interval set in the control panel has been reached. The plant is still working, but book a service so it stays that way.

Do you service and repair my make of plant?

We service and repair Klargester, Graf, WPL Diamond, Tricel, Rewatec (Conder) and Marsh plants, among others, across Surrey, Sussex, Kent, Hampshire and London. Our engineers carry most common parts.

The alarm keeps coming back after I reset it. What should I do?

Stop resetting it and call us. An alarm that returns means the fault is still there, and repeatedly resetting a tripped breaker can make an electrical fault worse.

Got a different question? Call 03333 233566 or send us a message.